APH techniek

All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C. 7 2/2-way solenoid valves brass Materials: Body: Brass, internal parts: Brass/stainless steel, seal: NBR (types with G 1 / 8 “ and G 1 / 4 “: FKM) Temperature range: -10°C to max. +85°C (types with G 1 / 8 “ and G 1 / 4 “: -10°C to max. +130°C), environment: -10°C to max. +50°C Media: Compressed air, neutral gases, water, neutral low-viscosity media, heating oil, other media on request Installation position: With upright magnets Voltages: Standard: 24V=, 230V AC, upon request: See order examples for other voltages, protection class: IP 65 Optional: FKM seal (-10°C to max. +130°C) -V , EPDM seal for air and warm water (-10°C to max. +120°C) -EP , EX protected** -EX 2/2-way solenoid valves from brass F P input 2 Order example: M 218 ** ** Standard type F Available voltages 24V= (standard) . . . . . . . . . . -24V= 230V AC (standard) . . . . . . . . -230V 12V= . . . . . . . . . . . . . . . . . . -12V= 48V= . . . . . . . . . . . . . . . . . . -48V= 24V AC . . . . . . . . . . . . . . . . . -24VAC 115V AC . . . . . . . . . . . . . . . . -115=V 48V AC . . . . . . . . . . . . . . . . . -48VAC Designation for the options: FKM seal . . . . . . . . . . . -V EPDM seal . . . . . . . . . . -EP EX protected** . . . . . . . . -EX G 1 / 8 “ & G 1 / 4 “ These valves are generally delivered with coils and plugs! For opening or closing, servo-controlled valves require a pressure difference between the valve inlet and valve outlet. The pres- sure difference is given as minimum pressure. There is a pressure compensation in the valve, resulting that no or little medium is used at the valve outlet, the valve will no longer function (it opens or closes unreliably). G 3 / 8 “ - G 2“ Type (DC) Type (AC) Op. pressure (bar) 24V= 230V AC Thread DN L DC/AC kv value 1) Closed (NC) without power M 218 24V= M 218 230V G 1 / 8 “ 2.2 38 0 - 16/0 - 15 2.4 l/min* M 214 24V= M 214 230V G 1 / 4 “ 2.2 38 0 - 16/0 - 15 2.4 l/min* M 238 24V= M 238 230V G 3 / 8 “ 13 67 0.3 - 16/0.3 - 16 55 l/min M 212 24V= M 212 230V G 1 / 2 “ 13 67 0.3 - 16/0.3 - 16 63 l/min M 234 24V= M 234 230V G 3 / 4 “ 21 82 0.3 - 16/0.3 - 16 100 l/min M 210 24V= M 210 230V G 1“ 25 96 0.3 - 16/0.3 - 16 160 l/min M 2114 24V= M 2114 230V G 1 1 / 4 “ 40 140 0.5 - 16/0.5 - 16 370 l/min M 2112 24V= M 2112 230V G 1 1 / 2 “ 40 140 0.5 - 16/0.5 - 16 400 l/min M 220 24V= M 220 230V G 2“ 50 168 0.5 - 16/0.5 - 16 540 l/min Open (NO) without power MO 218 24V= MO 218 230V G 1 / 8 “ 2.5 40 0 - 16/0 - 18 3.4 l/min MO 214 24V= MO 214 230V G 1 / 4 “ 3 40 0 - 8/0 - 15 4.5 l/min MO 238 24V= MO 238 230V G 3 / 8 “ 13 67 0.3 - 16/0.3 - 16 55 l/min MO 212 24V= MO 212 230V G 1 / 2 “ 13 67 0.3 - 16/0.3 - 16 63 l/min MO 234 24V= MO 234 230V G 3 / 4 “ 21 82 0.3 - 16/0.3 - 16 100 l/min MO 210 24V= MO 210 230V G 1“ 25 96 0.3 - 16/0.3 - 16 160 l/min MO 2114 24V= MO 2114 230V G 1 1 / 4 “ 40 140 0.5 - 16/0.5 - 16 370 l/min MO 2112 24V= MO 2112 230V G 1 1 / 2 “ 40 140 0.5 - 16/0.5 - 16 400 l/min MO 220 24V= MO 220 230V G 2“ 50 168 0.5 - 16/0.5 - 16 540 l/min * type AC: kv=4.5 l/min.** please indicate protection category, only NC-valves 1) water flow rate at +20°C, 1 bar pressure at the valve inlet, free discharge. Flow for air [l/min] ≈ 13.4 · kv · P input , if P output < (P input and P output are absolute values in bar.) 2 1 2 1 Liquid seals, gaskets & tapes from page 549 Especially good value! These valves are generally delivered with coils and plugs! 2/2-way solenoid valves from brass Eco-Line For opening or closing, servo- controlled valves require a pres- sure difference between the valve inlet and valve outlet. The pres- sure difference is given as minimum pressure. There is a pressure compensation in the valve, resulting that no or little medium is used at the valve outlet, the valve will no longer function (it opens or closes unreliably). 1) water flow rate at +20°C, 1 bar pressure at the valve inlet, free discharge, 3) magnetic coils and accessories from page 420 ** please enter required voltage, see order example G 1 / 8 “ & G 1 / 4 “ G 1 1 / 4 “ - G 2“ G 3 / 8 “ - G 1“ Type Closed (NC) Magnetic Type Open (NO) Magnetic Op. pressure (bar) without power coil 3) without power coil 3) Thread DN L NC / NO kv-value 1) ELP 18 ** Y ELPH 18 ** Z G 1 / 8 “ 3 39 0 - 13 / 0 - 8 3,2 l/min. ELP 14 ** Y ELPH 14 ** Z G 1 / 4 “ 3 39 0 - 13 / 0 - 8 3,2 l/min. ELP 38 ** Y ELPH 38 ** Z G 3 / 8 “ 15 66 0,5 - 16 / 0,5 - 13 64 l/min. ELP 12 ** Y ELPH 12 ** Z G 1 / 2 “ 15 66 0,5 - 16 / 0,5 - 13 64 l/min. ELP 34 ** Y ELPH 34 ** Z G 3 / 4 “ 20 75 0,5 - 16 / 0,5 - 13 108 l/min. ELP 10 ** Y ELPH 10 ** Z G 1“ 25 96 0,5 - 16 / 0,5 - 13 171 l/min. SLP 114 ** P --- --- G 1 1 / 4 “ 35 131 0,5 - 16 / --- 313 l/min. SLP 112 ** P --- --- G 1 1 / 2 “ 40 131 0,5 - 16 / --- 427 l/min. SLP 20 ** P --- --- G 2“ 50 165 0,5 - 16 / --- 684 l/min. F Order example: ELP 18 ** ** Standard type F Available voltages 24V= (standard) . . . . . . . . . . -24V= 230V AC (standard) . . . . . . . . -230V 12V= . . . . . . . . . . . . . . . . . . -12V= 24V AC . . . . . . . . . . . . . . . . . -24VAC Designation for the options: FKM seal . . . . . . . . . . . -V EPDM seal . . . . . . . . . . -EP Materials: Body: Brass, internal parts: Brass/stainless steel, seal: NBR (types with G 1 / 8 “ and G 1 / 4 “: FKM) Temperature range: -10°C to max. +80°C , environment: max. +50°C Media: Compressed air, neutral gases, water, neutral low-viscosity media, other media on request Installation position: With upright magnets Voltages: Standard: 24V=, 230V AC, upon request: See order examples for other voltages Protection class: IP 65 Optional: FKM seal (-10°C to max. +130°C) -V , EPDM seal for air and warm water (-10°C to max. +120°C) -EP 2 1 2 1 Closed (NC) without Power Open (NO) without Power Contact us for technical details 404 APH Techniek BV - Wateringen - T +31 (0)174 219 200 - sales@aphtechniek.nl - www.aphtechniek.nl

RkJQdWJsaXNoZXIy ODY1MjQ=