APH techniek

All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C. 6 Pressure regulators - Futura Thread R 014 F* R 014 FB* G 1 / 4 “ 0.5 - 8 bar 0 - 10 bar R 014-4 F R 014-4 FB G 1 / 4 “ 0.2 - 4 bar 0 - 6 bar R 014-10 F R 014-10 FB G 1 / 4 “ 0.5 - 10 bar 0 - 16 bar * standard series, please use preferentially as regulation range can be applied universally, ** installation of a standard pressure gauge only possible with a pressure gauge adapter, display range of the compact pressure gauge: 0 to 12 bar, or 0 to 6 bar * standard series, please use preferentially as regulation range can be applied universally, ** low own air consumption (2.6 l/min at output pressure of 6 bar) but therefore better hysteresis - almost independent of primary pressure, regulation accuracy: ± 25 mbar * standard series, please use preferentially as regulation range can be applied universally, ** low own air consumption (2.6 l/min at output pressure of 6 bar) but therefore better hysteresis - almost independent of primary pressure, regulation accuracy: ± 25 mbar Pressure regulators Futura model series 0 1 000 l/min 43 63 88 Coupling kit W 0 F KP 0 F or KPW 0 F W 0 F KP 0 F or KPW 0 F W 0 F KP 0 F or KPW 0 F Switch panel thread: M 30 x 1.5 Supply volume: Pressure regulator including pressure gauge Flow: 1000 l/min, relieving system: 25 l/min Pressure regulators Futura model series Version: Resettable (with relieving system) Materials: Body: Grivory® (PA 66), spring hood: POM, diaphragms and seals: NBR Temperature range: -10°C to max. +50°C Input pressure: Max. 16 bar (model series 0: max 12 bar) Pressure gauge connection: G 1 / 4 “ Media: Oiled and unoiled compressed air, neutral gases Advantages: Ÿ Automatic venting in the event of overpressure on the secondary side. Ÿ Simple assembly of single components using coupling kits within a model series. Ÿ Hand wheel can be locked by pressing down on it and bolted with a lock - please use VHS 20 (page 641) Model series 0 cannot be locked. ü Thread R 14 F* RP 14 F* G 1 / 4 “ 0.5 - 8 bar 0 - 10 bar R 14-1 F RP 14-1 F G 1 / 4 “ 0.1 - 1 bar 0 - 1.6 bar R 14-2 F RP 14-2 F G 1 / 4 “ 0.1 - 2 bar 0 - 2.5 bar R 14-4 F RP 14-4 F G 1 / 4 “ 0.2 - 4 bar 0 - 6 bar R 14-10 F RP 14-10 F G 1 / 4 “ 0.5 - 10 bar 0 - 16 bar R 14-16 F RP 14-16 F G 1 / 4 “ 0.5 - 16 bar 0 - 25 bar R 38 F* RP 38 F* G 3 / 8 “ 0.5 - 8 bar 0 - 10 bar R 38-1 F RP 38-1 F G 3 / 8 “ 0.1 - 1 bar 0 - 1.6 bar R 38-2 F RP 38-2 F G 3 / 8 “ 0.1 - 2 bar 0 - 2.5 bar R 38-4 F RP 38-4 F G 3 / 8 “ 0.2 - 4 bar 0 - 6 bar R 38-10 F RP 38-10 F G 3 / 8 “ 0.5 - 10 bar 0 - 16 bar R 38-16 F RP 38-16 F G 3 / 8 “ 0.5 - 16 bar 0 - 25 bar Pressure regulators Futura model series 1 up to 2 500 l/min 52 96 129 Coupling kit W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F W 1 F KP 1 F or KPW 1 F Switch panel thread: M 36 x 1.5 Supply volume: Pressure regulator incl. 50 mm pressure gauge Flow: G 1 / 4 “: 2000 l/min, G 3 / 8 “: 2500 l/min, relieving system: 70 l/min (precision pressure regulator 120 l/min) ATEX: Operating material without its own potential source of ignition in accordance with Directive 2014/34/EU Optional: Safety version: With upstream lockable ball valve and filler valve -Si Thread R 382 F* RP 382 F* G 3 / 8 “ 0.5 - 8 bar 0 - 10 bar R 382-1 F RP 382-1 F G 3 / 8 “ 0.1 - 1 bar 0 - 1.6 bar R 382-2 F RP 382-2 F G 3 / 8 “ 0.1 - 2 bar 0 - 2.5 bar R 382-4 F RP 382-4 F G 3 / 8 “ 0.2 - 4 bar 0 - 6 bar R 382-10 F RP 382-10 F G 3 / 8 “ 0.5 - 10 bar 0 - 16 bar R 382-16 F RP 382-16 F G 3 / 8 “ 0.5 - 16 bar 0 - 25 bar R 12 F* RP 12 F* G 1 / 2 “ 0.5 - 8 bar 0 - 10 bar R 12-1 F RP 12-1 F G 1 / 2 “ 0.1 - 1 bar 0 - 1.6 bar R 12-2 F RP 12-2 F G 1 / 2 “ 0.1 - 2 bar 0 - 2.5 bar R 12-4 F RP 12-4 F G 1 / 2 “ 0.2 - 4 bar 0 - 6 bar R 12-10 F RP 12-10 F G 1 / 2 “ 0.5 - 10 bar 0 - 16 bar R 12-16 F RP 12-16 F G 1 / 2 “ 0.5 - 16 bar 0 - 25 bar Pressure regulators Futura model series 2 up to 5 200 l/min 63 110 149 Coupling kit W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F W 2 F KP 2 F or KPW 2 F Switch panel thread: M 42 x 1.5 Supply volume: Pressure regulator incl. 50 mm pressure gauge Flow: G 3 / 8 “: 4500 l/min, G 1 / 2 “: 5200 l/min, relieving system: 70 l/min (precision pressure regulator 120 l/min) ATEX: Operating material without its own potential source of ignition in accordance with Directive 2014/34/EU Optional: Safety version: With upstream lockable ball valve and filler valve -Si F F Order example: R 14 F ** Designation for the options: With upstream, lockable ball valve and filler valve . . . . . -Si F Standard type Order example: R 380 F ** Designation for the options: With upstream, lockable ball valve and filler valve . . . . . -Si F Standard type Type with compact pressure gauge ** Type with 40 mm standard press. gauge Pressure gauge display Mounting bracket Pressure gauge display Mounting bracket Type standard Type precis. pressure regulators ** Pressure gauge display Mounting bracket Type standard Type precis. pressure regulators ** Pressure regulation range Pressure regulation range Pressure regulation range 322 APH Techniek BV - Wateringen - T +31 (0)174 219 200 - sales@aphtechniek.nl - www.aphtechniek.nl

RkJQdWJsaXNoZXIy ODY1MjQ=