APH techniek

All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C. 5 Electric rotary actuators Square Size Sanitary actuator ELS 230-1F03 16 ELS 24-1F03 19 F 03 9 1 10 Nm (12 Nm*) ELS 230-1F05VK9 16 ELS 24-1F05VK9 19 F 05 9 1 10 Nm (12 Nm*) ELS 230-1F05VK11 16 ELS 24-1F05VK11 19 F 05 11 1 10 Nm (12 Nm*) ELS 230-1F05 16 ELS 24-1F05 19 F 05 14 1 10 Nm (12 Nm*) Universal industrial actuator ELU 230-2F03 10 --- --- F 03 9 2 20 Nm (25 Nm*) ELU 230-2F05VK9 10 --- --- F 05 9 2 20 Nm (25 Nm*) ELU 230-2F05VK11 10 --- --- F 05 11 2 20 Nm (25 Nm*) ELU 230-2F05 10 --- --- F 05 14 2 20 Nm (25 Nm*) ELU 230-3F05VK11 10 --- --- F 05 11 3 35 Nm (38 Nm*) ELU 230-3F05 10 --- --- F 05 14 3 35 Nm (38 Nm*) ELU 230-4F05 14 --- --- F 05 14 4 55 Nm (60 Nm*) ELU 230-4F05VK17 14 --- --- F 05 17 4 55 Nm (60 Nm*) ELU 230-4F07VK14 14 --- --- F 07 14 4 55 Nm (60 Nm*) ELU 230-4F07 14 --- --- F 07 17 4 55 Nm (60 Nm*) ELU 230-5F07 30 --- --- F 07 17 5 85 Nm (90 Nm*) Special industrial actuator ELi 230-2F03-140 140 ELi 24-2F03-140 140 F 03 9 2 20 Nm (25 Nm*) ELi 230-2F05VK9-140 140 ELi 24-2F05VK9-140 140 F 05 9 2 20 Nm (25 Nm*) ELi 230-2F05VK11-140 140 ELi 24-2F05VK11-140 140 F 05 11 2 20 Nm (25 Nm*) ELi 230-2F05-140 140 ELi 24-2F05-140 140 F 05 14 2 20 Nm (25 Nm*) ELi 230-6F10*** 34 ELi 24-6F10*** 34 F 10 22 6 140 Nm (170 Nm*) ELi 230-7F10*** 58 ELi 24-7F10*** 58 F 10 22 7 300 Nm (350 Nm*) Retrofit kit "Battery Safety Return" for emg. closing (NC)/emg. opening (NO) if there is a power failure** ELi BSR --- ELi BSR --- --- --- --- --- * max. torque (not for continuous operation), ** not for sizes 6 and 7, *** IP 67 Advantages: • Mounting flange acc. to ISO 5211, • Manual emergency operation, • 2 additional limit switches • Torque cut-off, • Variable voltage (DC or AC) • Integrated heating in actuator housing Description: Electric rotary actuator with optical position indicator, manual emergency operation and switch room hea- ting. Two additional limit switches are installed for further control requirements. An electronic torque limiting unit prevents damage in the event of overload. The manual emergency operation can be done without dismantling the external clad- ding. Do not install upside down! Materials: Housing: PA 6 Temperature range: -20°C to max. +70°C Voltage: Type 230: 24 - 240V AC/DC (special ind. actuator: 85 - 240V AC/DC, sanitary actuator: 110 - 240V AC/DC), Type 24: 12 - 24V AC/DC (sanitary actuator: 24V AC/DC), (actuators can be powered with AC or DC voltage). Protection class: IP 67 (sanitary and special industrial actuator: IP 65) Power-on time: 75% Installation position: Arbitrary, but not at the top Optional (only for industrial actuator): "Battery Safety Return" for emergency closing NC (standard configuration) or emergency opening NO (changeover using jumpers) in case of power failure -BSR Electrically controlled rotary actuators F Order example: ELU 230-2F03 ** Designation for the options: Battery Safety Return . . . . . . . . . . . . . -BSR F Standard type ü special industrial actuator universal industrial actuator sanitary actuator A B D C Type Thread DN Ball valves with timer KH TiME 10 G 1“ 30 sec. 25 88 KH TiME 20 G 2“ 105 sec. 50 130 Remote control with 5 m cable KH TiME REMOTE Ball valves with time function PN 16 Materials: Ball valve housing: Brass nickel-plated, ball: Stainless steel, ball seals: PTFE, actuator housing: Plastic Temperature range: Medium: +1°C to max. +100°C, environment: +1°C to max. +50°C Media: Compressed air and other neutral media Power supply: 230V AC (clock and program are battery buffered) Protection class: IP 54 Programming: Accurate to the minute, up to 16 switching cycles per day, each weekday individually programmable Operation: Using timers (automatic), manual operation (timer switch) or manual operation (e.g. power failure). With ceiling installation, we recommend the use of remote controls. Advantage: Energy savings by automatically closing the compressed air line after work and automatically opening it before work starts ü type KH TiME 10 type KH TiME REMOTE Save energy with time-controlled automatic power disconnection TIP Warning: In case of high media temperatures, the actuator must be cooled! ISO 5211 Dimensions are found on page 310 Wiring diagram for ball valve (ISO5211) Working torque Type 24 Type 230 Install. length ball valve Regulating time Reg. time sec. Reg. time sec. APH Techniek BV - Wateringen - T +31 (0)174 219 200 - sales@aphtechniek.nl - www.aphtechniek.nl 315

RkJQdWJsaXNoZXIy ODY1MjQ=